![]() Mason (USA) Kinetics (USA) Christie & Grey (UK) Mason Weico Senior Flexonic Tozen Crane Sioux Chief (UK) Zurn (USA) Wade (UK) Aero flex Gulf flex MobiusĪCCEPTABLE MANUFACTURERS / SUPPLIERS Mason (USA) Kinetics (USA) Manson ( USA) Mupro (Germany) Trerice (USA) Weiss (USA) Dwyer (USA) Hunter (USA) Armstrong (USA) Spirax Sarco (UK) Econosto (Holland) Crane Co. Greenheck Pillinger Holden & Broke ITT Bell and GossettĪCCEPTABLE MANUFACTURERS / SUPPLIERS Saudi Steel Pipe (KSA) Grinnell(USA) Nippon Steel (Japan) Sumitomo van Leeuwenīlack Steel Pipes and Fittings (Chilled Water)īaltimore (USA) Culligan (USA) Dearborn (UK) Houseman (UK) Corodex Waterbird Crane (UK) Econosto (Holland) Hattersley (UK) Tour & Anderson (Canada) Pegler Moneywell (Germany) Griswold Crane (UK) Econosto (Holland) Hattersley (UK) Tour & Anderson (Canada) H. Graundfos KSB ITT Bell and Gossett SPP Holden & Brooke Trane Mekar Climatrol Europe York Trane Carrier Trane SPC Climatrol Europe York Trane Carrier Country of Origin, where listed, must be complied.ĪCCEPTABLE MANUFACTURERS / SUPPLIERS HVAC 1 Water Cooled Chillers Trane Carrier York trane York Mekar USA / West Europe Euroclima Climatrol VTS clima CONTACT DETAILS Materials proposed form listed Makes also must fully comply with Detailed Specification. No alternative Makers shall be accepted unless all the listed Makers are unavailable. Gulf House Engineering January 2010 SCHEDULE OF MANUFACTURERS All the materials supplied under this contract shall be from one of the manufacturers listed below. LIST OF MANUFACTURERS / SUPPLIERS or EQUALĠ7-C106 NOVOTEL AL DANA RESORT TOWERS SECTION 15007 ACCEPTABLE MANUFACTURERS/SUPPLIERS OR EQUAL SECTION 15007 15010 15060 15100 15120 15240 15255 15400 15405 15500 15510 15540 15545 15650 15800 15850 15865 15885 15890 15910 15940 15990 15995ĭESCRIPTION ACCEPTABLE MANUFACTURES/SUPPLIERS OR EQUAL MECHANICAL GENERAL PROVISIONS HANGERS AND SUPPORTS ACMV VALVES PIPING SPECIALTIES SOUND & VIBRATION CONTROL MECHANICAL INSULATION PLUMBING DRAINAGE FIRE FIGHTING ACVM PIPEWORK ACVM PUMPS CHEMICAL WATER TREATMENT REFRIGERATION EQUIPMENT SPLIT MULTI-SPLIT AIR-CONDITIOING AIR HANDLING & FAN COIL UNITS FANS AIR FILTERS SHEET METAL DUCTWORK ACCESSORIES AIR TERMINALS CONTROL CENTRE INTERFACING TESTING & BALANCE Ġ7-C106 NOVOTEL AL DANA RESORT TOWERS MECHANICAL, HVAC, & PLUMBING SPECIFICATION ![]() Report Distribution Swiss Planning Group Gulf House Engineering (signature & date) (signature & date) No. ![]() Project Manager Approval Director Approval Riffat Al Waheeb Reviewer 11th January 2010 Mechanical, HVAC & Plumbing Specification Gulf House Engineering ARCHITECTURAL & ENGINEERING CONSULTANCY ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |